Feature Summary
|

- General
- Single size Eurocard 3U 100x157mm2
- Front panel width 8HP
- PwrBlade® backplane connector (+12V DC input, +12V DC output)
- +12V DC input via PwrBlade® P4/P5 (external cable assembly, from external power supply)
- Option +12V DC input via PwrBlade® P6/P8 (custom backplane routing)
- Custom CompactPCI® Serial backplanes w. dual power slots available, for removable power supply and SRU-UPS adjacent in-line
- UPS
- In-line operation with additional power supply
- For usage on a standard backplane PwrBlade® slot - DC input pins P4/P5 (option 1)
- For usage on a custom backplane PwrBlade® slot - DC input pins P6/P8 (option 2)
- Custom backplanes w. dual power slots available (PSU & UPS)
- Normal operation is +12V input to output bypass mode
- Backup operation is automatically entered when input power failure occurs
- Input voltage 12VDC (11.6VDC to 16VDC)
- Input current 5.8A nom.
- Output power 60W both modes normal (bypass) and backup
- Output voltage normal (bypass) mode VIN - 0.3V @100% load
- If possible, adjust input voltage to +12.3VDC for compensation of voltage loss
- Output voltage backup mode +12VDC ±2%, <30mV ripple, 97% efficiency typ.
- Backup time vs. load current @25°C typ. 14s @5A, 20s @3.5A, 35s @2A, 70s @1A
- Power fail detection when input voltage falls below +11.5VDC
- Backup power source on-board super capacitors 4 x 100F
- Intelligent capacitor charge sharing
- Charge current up to 6.2A depending on output load
- Charge time w/o output load <60s
- Charge time w. full output load ~150s
- Operating temperature -20°C to +70°C
- Option power fail output signal
- CPU Card UEFI (BIOS) support for OS emergency shutdown on power fail
- Available for SC4-CONCERTO, SC5-FESTIVAL (PWR_FAIL#), and PC7-FESTIVAL (FAL#)
- UEFI Setup allows variable delay and additional settings
- Special Features
- FCI/Amphenol PwrBlade® backplane header, 9 x power 24 x signal contacts
- Pin assignment similar to nVent and Trenew removable power supplies (AC contacts = NC)
- COTS CompactPCI® Serial backplane available with two adjacent (8HP pitch) PwrBlade® slots for removable power supply and and SRU-UPS (EKF part no. 932.8.04.998)
- Backplane usage is scalable - if an UPS is not required power supply can be moved into UPS slot
- Custom backplane solutions CompactPCI® Serial or other Eurocard based available on request
- Front handle micro-switch can be used as system power button replacement
- Applications
- Short time backup solution e.g. bridging the time gap from general power failure to emergency generator startup
- Can be used to backup the system until normal shutdown of the operating system has been accomplished (shutdown initiated by power fail output signal from PSU or UPS)
- System reliability enhancement for critical mains supply
- Environmental & Regulatory
- Designed & manufactured in Germany
- Certified quality management according to ISO 9001
- Long term availability
- Rugged solution (coating, sealing, underfilling on request)
- RoHS compliant
- Operation temperature -20°C to +70°C
- Storage temperature -20°C to +70°C
- Humidity 5% ... 95% RH non condensing
- Altitude -300m ... +3000m
- Shock 15g 0.33ms, 6g 6ms
- Vibration 1g 5-2000Hz
- MTBF 230.6 years (carrier board, w/o mezzanine card)
- EC Regulatory EN55024, EN55032, EN62368-1 (CE)

|